X20BT9400 X2X Link bus Transmitter B&R Supplier in China

Products Mode: X20BT9400
Place of Origin: AT

Inquery Now
Description
X20BT9400 X2X Link bus Transmitter 
 
MATERIAL NUMBER:
X20BT9400
DESCRIPTION:
  • X2X Link bus transmitter
  • For seamless expansion of the system
  • Up to 100 m segment length
  • Supply for internal I/O power supply
  • Integrated X2X Link power supply of the X67 system
  • Operation only on the rightmost slot

To connect an X20 system to an X67 system, a bus transmitter is simply connected to the end of the X20 block so that the X2X Link cable can be clamped. The bus transmitter also provides the X2X Link supply voltage of the X67 system. The X67 system power supply module that was previously always necessary can be omitted.

Short description
Bus transmitter X2X Link bus transmitter with supply for I/O and integrated X67 system power supply
General information
B&R ID code 0xA238
Status indicators X2X bus function, operating state, module status
Diagnostics  
Module run/error Yes, using LED status indicator and software
X2X bus function Yes, using LED status indicator
Power consumption for X2X Link power supply  1.38 W
Power consumption   
Bus 0.5 W
Internal I/O  
As bus transmitter 0.1 W
Additionally as supply module 0.6 W
Additional power dissipation caused by actuators (resistive) [W] -
Certifications  
CE Yes
UKCA Yes
ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X
UL cULus E115267
Industrial control equipment
HazLoc cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5
EAC Yes
KC Yes
X67 X2X Link power supply input
Input voltage 24 VDC -15% / +20%
Input current Max. 0.5 A
Fuse Integrated, cannot be replaced
Reverse polarity protection Yes
X67 X2X Link power supply output
Parallel connection with X67PS1300 Yes 
Overload characteristics Temporarily short-circuit and overload-proof
Observe the corresponding status message (LED "I") or evaluate the software status.
X67 modules supplied by BT9400  
Horizontal mounting orientation Max. 8 (nominal output power: 6 W)
Vertical mounting orientation Max. 6 (nominal output power: 4.5 W)
Input I/O power supply
Input voltage 24 VDC -15% / +20%
Fuse Required line fuse: Max. 10 A, slow-blow
Reverse polarity protection No
Output I/O power supply
Nominal output voltage 24 VDC
Behavior on short circuit Required line fuse
Permissible contact load 10 A
Operating conditions
Mounting orientation  
Horizontal Yes
Vertical Yes
Installation elevation above sea level  
0 to 2000 m No limitation
>2000 m Reduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529 IP20
Ambient conditions
Temperature  
Operation  
Horizontal mounting orientation -25 to 60°C
Vertical mounting orientation -25 to 50°C
Derating -
Storage -40 to 85°C
Transport -40 to 85°C
Relative humidity  
Operation 5 to 95%, non-condensing
Storage 5 to 95%, non-condensing
Transport 5 to 95%, non-condensing
Mechanical properties
Note Order 1x terminal block X20TB12 separately.
Order 1x bus module X20BM11 or 1x bus module X20BM15 separately.
Pitch 12.5+0.2mm