Home
About
Company Profile
How to order
Terms of Service
Productlines
Encoders
Rotary Encoders
Angle Encoders
Linear Encoders
Glass Discs
Electronic/Controls
PLC/DCS Modules
Electronic Drives & Controls
Hydraulic and Pneumatic
Hydraulic Valves
Hydraulic Pumps
Hydraulic Motors
Pneumatic instruments
Other Products
View All
Brands
HEIDENHAIN
PRECIZIKA
RSF
SIEMENS
B&R
AVENTICS/EMERSON
EMG
REXROTH
MOOG
PARKER
HYDAC
EATON/VICKERS
HAWE
ATOS
Solution
Hydraulic System
CNC retrofit projects
Motion Control Solutions
Automation Lines
Marine Port Machinery
Industrial Machines
Mobile Hydraulic Industry
Blog
Contact
Productlines
B&R
X20DO4332 B&R X20 Output Module - B&R Supplier in China
Products List
Encoders
Rotary Encoders
Angle Encoders
Linear Encoders
Glass Discs
Electronic/Controls
PLC/DCS Modules
Electronic Drives & Controls
Hydraulic and Pneumatic
Hydraulic Valves
Hydraulic Pumps
Hydraulic Motors
Pneumatic instruments
Brands
HEIDENHAIN
PRECIZIKA
RSF
SIEMENS
B&R
AVENTICS/EMERSON
EMG
REXROTH
MOOG
PARKER
HYDAC
EATON/VICKERS
HAWE
ATOS
Other Products
Featured Products
AVENTICS Series LS04 Directional valves
AVENTICS Series 581 valves
AVENTICS Series WV02 Directional valves
AVENTICS Series ST Directional valves
AVENTICS Series AS3 Air Preparation Units
AVENTICS Series AS5 Air Preparation Units
AVENTICS Series AS2 Air Preparation Units
AVENTICS Series AS1 Air Preparation Units
Rexroth Solenoid Valve 4WE STOCKS FOR SALE
Rexroth Axial Piston Variable pump A4VSO
Rexroth Piston Pump A10VSO 32 - with Fast Delivery
Flow Control Valves 2FRM - Bosch Rexroth Valve for Sale
X20DO4332 B&R X20 Output Module - B&R Supplier in China
Products Mode:
X20DO4332
Place of Origin:
AT
Add to Basket
Inquery Now
Prev
Next
Description
X20DO4332 B&R X20 Output Module
MATERIAL NUMBER:
X20DO4332
DESCRIPTION:
4 digital outputs with 2 A
Source connection
3-wire connections
24 VDC and GND for actuator supply
Integrated output protection
OSP mode
The module is equipped with 4 outputs for 3-wire connections. The rated output current is 2 A.
Short description
I/O module
4 digital outputs 24 VDC for 3-wire connections
General information
B&R ID code
0x1B9C
Status indicators
I/O function per channel, operating state, module status
Diagnostics
Module run/error
Yes, using LED status indicator and software
Outputs
Yes, using LED status indicator and software (output error status)
Power consumption
Bus
0.16 W
Internal I/O
0.49 W
Additional power dissipation caused by actuators (resistive) [W]
+1.6 (Rev. <H0: +2.24)
Certifications
CE
Yes
UKCA
Yes
ATEX
Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X
UL
cULus E115267
Industrial control equipment
HazLoc
cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5
EAC
Yes
KC
Yes
Digital outputs
Variant
Current-sourcing FET
Nominal voltage
24 VDC
Switching voltage
24 VDC -15% / +20%
Nominal output current
2 A
Total nominal current
8 A (Rev. <H0: 4 A)
Connection type
3-wire connections
Output circuit
Source
Output protection
Thermal shutdown in the event of overcurrent or short circuit (see value "Short-circuit peak current")
Internal freewheeling diode for switching inductive loads (see section "Switching inductive loads")
Actuator power supply
0.5 A in total for output-independent actuator power supply
Diagnostic status
Output monitoring with 10 ms delay
Leakage current when the output is switched off
5 µA
R
DS(on)
100 mΩ (Rev. <H0: 140 mΩ)
Peak short-circuit current
<4 A (Rev. <H0: <12 A)
Switch-on in the event of overload shutdown or short-circuit shutdown
Approx. 10 ms (depends on the module temperature)
Switching delay
0 → 1
<300 µs
1 → 0
<300 µs
Switching frequency
Resistive load
Max. 500 Hz
Inductive load
See section "Switching inductive loads".
Braking voltage when switching off inductive loads
Typ. 50 VDC
Insulation voltage between channel and bus
500 V
eff
Additional functions
Outputs can be connected in parallel to increase the output current.
Actuator power supply
Voltage
Module power supply minus voltage drop for short-circuit protection
Voltage drop for short-circuit protection at 500 mA
Max. 2 V
Short-circuit proof
Yes
Power consumption
Actuator power supply
Max. 12 W
Electrical properties
Electrical isolation
Channel isolated from bus
Channel not isolated from channel and I/O power supply
Operating conditions
Mounting orientation
Horizontal
Yes
Vertical
Yes
Installation elevation above sea level
0 to 2000 m
No limitation
>2000 m
Reduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529
IP20
Ambient conditions
Temperature
Operation
Horizontal mounting orientation
-25 to 60°C
Vertical mounting orientation
-25 to 50°C
Derating
See section "Derating".
Storage
-40 to 85°C
Transport
-40 to 85°C
Relative humidity
Operation
5 to 95%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Mechanical properties
Note
Order 1x terminal block X20TB12 separately.
Order 1x bus module X20BM11 separately.
Pitch
12.5
+0.2
mm
Related Products
B&R ACOPOS Servo Motion Control System
B&R X20 Module System I/O System STOCKS FOR SALE
X20PS9400 B&R X20 System - in Stock China
X20DO9322 B&R X20 System - in Stock China